• RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water
  • RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water
  • RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water
  • RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water
  • RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water
  • RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

After-sales Service: 1 Year Lifetime Fee Technical Support
Warranty: 1 Year Lifetime Fee Technical Support
Display: Digital
Appliance: Food Analysis, Medical Research, Biochemistry, Water Treatment
Portable: Non Portable
Certification: CE, ISO9001, SGS
Samples:
US$ 259.8/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Jiangsu, China
to see all verified strength labels (30)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Application
  • Company Profile
  • Warehouse and Factory
  • procedures
  • Certifications
Overview

Basic Info.

Model NO.
ADS2-CL3A
Analog Output
Two 0/4~20mA Current Output with a Maximum Load of
Resolution
0.001 Mg/L
Communication
RS485 Modbus RTU
Relay Output
Two Spst Relays
Protection Level
IP66
Shell Material
ABS
Weight
About 800g
Certificate
CE ISO9001 SGS Rosh
Transport Package
Packaging
Specification
144*144*120mm
Trademark
drfn
Origin
China
HS Code
9027809990
Production Capacity
50000 Pieces/Year

Product Description

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

Product Description

Features& Advantages

3.2-inch large LCD screen

User-friendly Chinese and English language interface

Password can be set to prevent misoperation

2 SPST multi-function and settable relays

0/4~20mA active current loop output

RS485 interface, Modbus RTU communication protocol

Shortcut button helps you perform daily maintenance quickly

Provides AC and DC power supply modes, both of which are wide voltage power supply

IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas

Support a variety of installation methods, can be applied to more different installation environment

Product Parameters

Specification Of Digital PH Meter
 

Model ADS2-U3A
software version Daruifuno residual chlorine analysis softwareV 1.0
Display Range 0.00-200.00mg/L
Resolution 0.001 mg/L
Meter performance Accurancy Better than 0.15% of the measurement range
Stability 0.05% of measurement range every 24 hours, no accumulation
repeatability Better than 0.1% of the measurement range
Sensor diagnosis Image display with buzzer warning
Relay output Two SPST relays with a maximum load of 3A/250VAC
Analog output Two 0/4~20mA current output with a maximum load of 1000Ω.
Communication RS485  Modbus RTU / JSON text data format
OTA --
Display screen 128*64 black and white dot matrix LCD, adjustable backlight mode, adjustable display rate.
Configuration Power failure protection, indefinite retention of parameters
Time/Data recording year/month/day/hour/minite/second,Record 14,000 historical data;
maintenance record Save the last 100 maintenance data
Protection Grade IP66
Operating Temperature 0~60ºC, RH<95%, non-condensing
Storage Temperature -20~70ºC, RH<55%, non-condensing
Enclosure Material Inhanced ABS;
Dimension 144*144*120mm
Installation Method wall mounting, pipe clamp, panel
Hole Size 138*138mm
Power supply 100~240VAC
Power Consumption About 10W
Weight About 800g

Detailed Photos

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

 

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

Application

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

Company Profile

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

Warehouse and Factory

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water
RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

procedures

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

Certifications

RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

FAQ
Q: Is your company a manufacturer?
A: Our company is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. The quality of our products is guaranteed strictly.
 
Q: What's the location of your company?
A: Our company is Located in Suzhou near Shanghai,So we enjoy convenient water, land and air transportation,which is very efficient and fast.

Q: How is your service?
A: We will try our best to offer you good before-sale and after-sale service. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.

Transportation
RS485 Modbus Residual Chlorine Tester Ec/Do/Tu/Cod/pH/ORP/Cl Meter for Drinking Water

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now